The article presents a review of the literature about modern aspects of endoillumination systems used for vitrectomy: a brief history of their development is presented, modern and prospective sources of illumination are described, their basic physical parameters and the risk of phototoxic hazard during the implementation of endovitreal interventions is discussed.

About the Authors

R. R. Yamgutdinov
ГБУЗ РБ «Городская клиническая больница» №10 г. Уфы; ФГБОУ ВО «Башкирский государственный медицинский университет» Минздрава России
Russian Federation


T. R. Mukhamadeev
ЗАО «Оптимедсервис»; ФГБОУ ВО «Башкирский государственный медицинский университет» Минздрава России
Russian Federation


A. G. Yamlikhanov
ГБУЗ РБ «Городская клиническая больница» №10 г. Уфы; ФГБОУ ВО «Башкирский государственный медицинский университет» Минздрава России
Russian Federation


T. I. Dibaev
ЗАО «Оптимедсервис»; ФГБОУ ВО «Башкирский государственный медицинский университет» Минздрава России
Russian Federation


B. M. Aznabaev
ЗАО «Оптимедсервис»; ФГБОУ ВО «Башкирский государственный медицинский университет» Минздрава России
Russian Federation


References

1. Влияние витальных красителей на свободнорадикальное окисление в модельных системах / Б.М. Азнабаев [и др.] // Практическая медицина. - 2017. - Т. 110. - С. 12-15

2. Эндоиллюминация в ходе витреальной хирургии - эволюция вопроса и особенности применения на современном этапе / С.Н. Казиев [и др.] // Практическая медицина. - 2013. - Т. 70 - C. 10-12

3. Кислицина, М.И. Хромовитректомия / М.И. Кислицина, С.В. Новиков, С.В. Беликова // Практическая медицина. - 2012. - Т.59. - C. 63-67

4. Островский, М.А. Молекулярные механизмы повреждающего действия света на структуры глаза и системы защиты от такого повреждения / М.А. Островский // Успехи биологической химии. - 2005. - Т. 45. - С. 173-204

5. Minimal endoillumination levels and display luminous emittance during three-dimensional Heads-up vitreoretinal surgery / M.K. Adam [et al.] // Retina. - 2016. - Vol. 0. - P. 1-4

6. LED illuminator / A.N. Artsyukhovich [et al.] // Patent USA., №20120051042A1, 2012

7. Ophtalmicendoillumination using fiber generated light. / A.N. Artsyukhovich [et al.] // Patent USA., №20100182569A1, 2010

8. Retinal endoilluminator toxicity of xenon and light-emitting diode (LED) light sources: rabbit model / B. Aydin [et al.] // Cutaneous and Ocular Toxicology. - 2014. - Vol. 3. - P. 192-196

9. Multi-LED ophthalmic illuminator / M.J. Buezek [et al.] Patent USA, №2008024692A1, 2008

10. Charles, S. Illumination and phototoxicity issues in vitreoretinal surgery/ S. Charles // RETINA. - 2008. - Vol. 28. - P. 1-4

11. Vitreoretinal instruments: vitrectomy cutters, endoillumination and wide-angle viewing systems / P.R. Chaves de Oliveira [et al.] // International Journal of Retina and Vitreous. - 2016. -Vol. 0. - P. 1-15

12. Chow, D.R. Tips on improving your use of endoillumination / D.R. Chow // Retin. Physician. - 2011. - Vol. 8, № 4. - Р. 43-46

13. Vital dyes and light sources for chromovitrectomy: comparative assessment of osmolarity, pH, and spectrophotometry/ P. Costa Ede [et al.] // Invest Ophthalmol Vis Sci. - 2009. - Vol. 50, №1. - P.385-391

14. Rhodopsin-mediated blue-light damage to the rat retina: effect of photoreversal of bleaching / C. Grimm [et al.] // Invest. Ophthalmol. Vis. Sci. - 2001. - Vol. 42. - Р. 497-505

15. Action spectrum for retinal injury from near-ultraviolet radiation in the aphakic monkey / W.T. Ham [et al.] // Am. J. Ophth. - 1982. - Vol. 93. - P. 299-306

16. The nature of retinal radiation damage: dependence on wavelength, power level and exposure time / W.T. Ham [et al.] // Vision Res. - 1980. - Vol. 20. - Р. 1105-1111

17. Histology of the vitreoretinal interface after indocyanine green staining of the ILM, with illumination using a halogen and xenon light source/ C. Haritoglou [et al.] // Invest Ophthalmol Vis Sci. - 2005. - Vol. 46, №4. - P.1468-1472

18. White light emitting diod (LED) illuminator for ophthalmic endoillumination / C. Horvath [et al.] // Patent USA, №20110037948A1, 2011

19. Vitrectomy. A pars plana approach / R. Machemer [et al.] // Trans. Am. Acad. Ophthalmol. Otolaryngol. - 1971. - Vol. 75. - Р. 813-820

20. Machemer, R. Vitrectomy: a pars plana approach. Technical improvements and further results / R. Machemer, J.M. Parel, E.W. Norton // Trans. Am. Acad. Ophthalmol. Otolaryngol. - 1972. - Vol. 76. - P. 462-466

21. McCannel, C.A. Advanced in endoillumination / C.A. McCannel // Retinal physician. - 2015. -Vol. 12. - P. 9-10

22. O'Malley, C. Electrovitrectomy. Principles and results / C. O'Malley, R.M. Heintz // Br. J. Ophthalmol. - 1975. - Vol. 59, № 10. - Р. 580-585

23. MicroincisionVitrectomy Surgery. Emerging Techniques and Technology / H. Oh [et al.] // Dev. Ophthalmol. Basel, Karger, 2014. - Vol. 54. - P. 23-30

24. Peyman, G.A. Improved vitrectomy illumination system / G.A. Peyman // Am. J. Ophthalmol. - 1976. - Vol. 81. - Р. 99-100

25. Rodrigues, E.B. Chromovitrectomy: a new field in vitreoretinal surgery / E.B.Rodrigues, C.H. Meyer, P. Kroll // Graefes Arch Clin-ExpOphthalmol. - 2005. - Vol. 243, №4. - P.291-293

26. Van den Biesen P.R. Endoillumination during vitrectomy and phototoxicity thresholds / P.R. Van den Biesen [et al.] // Br. J. Ophthalmol. - 2000. - Vol. 84. - Р. 1372-1375

27. Intraretinal oxygen distribution in the monkey retina and the response to systemic hyperoxia / D.Y. Yu [et al.] // Invest. Ophthalmol. Vis. Sci. - 2005. - Vol. 46, № 12. - Р. 4728-4733


Review

For citations:


Yamgutdinov R.R., Mukhamadeev T.R., Yamlikhanov A.G., Dibaev T.I., Aznabaev B.M. BRIGHTNESS AND PHOTOTOXICITY - TWO SIDES OF ENDOILLUMINATION. Bashkortostan Medical Journal. 2018;13(1):127-131. (In Russ.)

Views: 72


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 1999-6209 (Print)